CHEMVEN

Selective Precipitation: Nickel in Presence of Cobalt

Determine nickel in a Ni-Co alloy, demonstrating the selectivity of DMG for nickel.

Level: UniversitySafety: SafeTime: 2 h
Aim of Experiment: Determine nickel in a Ni-Co alloy, demonstrating the selectivity of DMG for nickel.

Theoretical Foundations

Cobalt(II) forms a soluble brown complex with dimethylglyoxime in ammoniacal solution but no precipitate, whereas nickel gives the insoluble scarlet Ni(HDMG)2: Ni2+ + 2 H2DMG → Ni(HDMG)2(s) + 2H+. Hence nickel can be determined directly in the presence of cobalt without prior separation — a classic example of a selective organic precipitant.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Analytical balance
  • 400 mL beaker
  • Hot plate
  • Sintered-glass crucible
  • Oven
  • Desiccator

Chemical Reagents

  • Ni-Co alloy sample
  • Hydrochloric acid, dilute
  • Nitric acid, dilute
  • Dimethylglyoxime solution, 1% in ethanol
  • Ammonia solution, dilute
  • Distilled water

Step-by-Step Practical Procedure

  1. Weigh accurately 0.3 g of alloy; dissolve in dilute HCl with a few drops of HNO3.
  2. Dilute to 150 mL; heat to 70-80 C.
  3. Add 25 mL 1% DMG solution with stirring.
  4. Add dilute ammonia to pH 8-9; the solution turns brown (Co complex) and scarlet Ni(HDMG)2 precipitates.
  5. Digest warm 30 minutes; filter through a weighed sintered-glass crucible.
  6. Wash well with hot water to remove the soluble cobalt complex; dry at 150 C to constant mass and weigh.

Observations & Expected Results

Brown solution with scarlet precipitate; washings run brown then colourless. Typical precipitate mass about 0.9 g from 0.3 g alloy.

Worked Stoichiometric Calculations

Problem: 0.3000 g of Ni-Co alloy gave 0.8850 g Ni(DMG)2. Calculate % Ni (cobalt by difference).

Working: Mass Ni = 0.8850 × 0.2032 = 0.1798 g. % Ni = (0.1798/0.3000) × 100 = 59.94% ≈ 59.9% Ni; % Co ≈ 40.1% by difference.

Safety Precautions & Hazard Control

  • Wash thoroughly; adsorbed brown cobalt complex would give high results.
  • Do not let the solution become too ammoniacal, which can precipitate Co(OH)3 on standing.
  • Add DMG before the ammonia so nickel is captured as it is liberated.

Waste Disposal Protocol

Cobalt/nickel filtrates to heavy-metal waste.

Viva Voce Oral Defense Questions & Answers

Q: Why is no prior separation of cobalt needed?

A: Cobalt forms a soluble DMG complex under these conditions while nickel's chelate precipitates, so the reagent itself effects the separation.

Q: What would happen if washing were incomplete?

A: Adsorbed brown cobalt complex would add mass to the precipitate, giving a positive error in nickel.

← Back to Experiments Directory