CHEMVEN

Nickel in Electroplating Bath by DMG Gravimetry

Determine the nickel concentration (g/L) of a Watts nickel plating bath.

Level: UniversitySafety: SafeTime: 2 h
Aim of Experiment: Determine the nickel concentration (g/L) of a Watts nickel plating bath.

Theoretical Foundations

Plating baths are monitored to keep metal concentration in range. An aliquot of bath is diluted and nickel precipitated directly: Ni2+ + 2 H2DMG → Ni(HDMG)2(s) + 2H+. Boric acid and chloride in the bath do not interfere. GF = 0.2032; dividing by the aliquot volume gives g/L Ni.

Required Apparatus & Chemicals

Laboratory Apparatus

  • 10 mL pipette
  • Analytical balance
  • 400 mL beaker
  • Hot plate
  • Sintered-glass crucible
  • Oven
  • Desiccator

Chemical Reagents

  • Nickel plating bath sample
  • Dimethylglyoxime solution, 1% in ethanol
  • Ammonia solution, dilute
  • Distilled water

Step-by-Step Practical Procedure

  1. Pipette 10.00 mL of bath into a 400 mL beaker; dilute to 150 mL.
  2. Heat to 70-80 C; add 25 mL 1% DMG solution with stirring.
  3. Add dilute ammonia dropwise to pH 8-9; digest warm 30 minutes.
  4. Filter through a weighed sintered-glass crucible; wash with hot water.
  5. Dry at 150 C to constant mass and weigh.
  6. Calculate g/L Ni in the bath.

Observations & Expected Results

Scarlet precipitate; typical mass 0.4-0.6 g from 10 mL of bath.

Worked Stoichiometric Calculations

Problem: 10.00 mL of plating bath gave 0.4820 g Ni(DMG)2. Calculate the bath nickel concentration in g/L.

Working: Mass Ni = 0.4820 × 0.2032 = 0.09794 g in 10.00 mL. Concentration = 0.09794 g / 0.01000 L = 9.79 g/L Ni.

Safety Precautions & Hazard Control

  • Pipette the viscous bath sample carefully and rinse the pipette into the beaker.
  • Maintain pH 8-9; too acidic gives incomplete precipitation.
  • Dry to constant mass.

Waste Disposal Protocol

Nickel filtrates to heavy-metal waste; ethanol to organic waste.

Viva Voce Oral Defense Questions & Answers

Q: Why is bath nickel concentration controlled?

A: It governs the plating rate, deposit quality and throwing power; too low gives burnt deposits, too high wastes chemicals.

Q: Do boric acid and chloride in the bath interfere?

A: No — neither forms an insoluble DMG compound, and both stay in solution under the precipitation conditions.