Trace Chloride in Boiler Feed Water
Determine trace chloride in boiler feed water, where chloride causes turbine corrosion.
Theoretical Foundations
Chloride in boiler feed water must be kept very low (often < 2 mg/L) because it concentrates in the boiler and causes stress-corrosion cracking of turbine blades. A full litre of sample is taken so that the AgCl precipitate is weighable: Ag+ + Cl- → AgCl(s), GF = 0.2473. A reagent blank is run alongside.
Required Apparatus & Chemicals
Laboratory Apparatus
- 1 L measuring cylinder
- Analytical balance
- 1 L beaker (foil-wrapped)
- Hot plate
- Sintered-glass crucible
- Oven
- Desiccator
Chemical Reagents
- Boiler feed water sample
- Silver nitrate solution, 0.1 M
- Nitric acid, dilute
- Distilled water (for blank)
Step-by-Step Practical Procedure
- Measure 1.00 L of feed water into a foil-wrapped beaker; add 3 mL dilute HNO3.
- Evaporate gently to about 150 mL to concentrate the chloride.
- Heat to near boiling and precipitate with AgNO3 dropwise.
- Digest warm, filter through a weighed sintered-glass crucible, wash with dilute HNO3.
- Dry at 150 C to constant mass and weigh; subtract the blank AgCl mass.
- Calculate chloride in mg/L.
Observations & Expected Results
Barely visible turbidity at first; after evaporation a definite white precipitate. Typical net AgCl mass 0.004-0.010 g per litre.
Worked Stoichiometric Calculations
Problem: 1.00 L of feed water gave 0.0062 g AgCl (blank negligible). Calculate chloride in mg/L.
Working: Mass Cl = 0.0062 × 0.2473 = 0.001533 g = 1.533 mg. Concentration = 1.53 mg/L Cl, within a typical 2 mg/L limit.
Safety Precautions & Hazard Control
- Run a full reagent blank; at trace levels reagents contribute measurably.
- Evaporate gently without baking dry.
- Avoid chloride contamination from hands and glassware; rinse everything with distilled water.
Waste Disposal Protocol
Silver residues collected for recovery.
Viva Voce Oral Defense Questions & Answers
Q: Why is chloride dangerous in boilers?
A: It concentrates by evaporation in the boiler, breaks down protective oxide films and causes pitting and stress-corrosion cracking of steel and turbine alloys.
Q: Why is a blank essential at trace levels?
A: Reagents and glassware contribute chloride comparable to the sample level; the blank corrects for this systematic positive error.