Barium in Barium Chloride Dihydrate: Reverse Gravimetry
Determine barium in BaCl2·2H2O by precipitating it as BaSO4 (reverse precipitation).
Theoretical Foundations
Gravimetry works in either direction: here the analyte cation Ba2+ is precipitated with excess sulfate: Ba2+(aq) + SO4 2-(aq) → BaSO4(s). The procedure mirrors sulfate determination — hot dilute acid, slow addition of precipitant, digestion, washing and ignition. The gravimetric factor for barium is M_Ba / M_BaSO4 = 137.33 / 233.39 = 0.5884.
Required Apparatus & Chemicals
Laboratory Apparatus
- Analytical balance
- 400 mL beakers
- Hot plate
- Ashless filter paper
- Muffle furnace
- Desiccator
- Wash bottle
Chemical Reagents
- Barium chloride dihydrate sample
- Sulfuric acid, dilute (1 M)
- Hydrochloric acid, dilute
- Distilled water
Step-by-Step Practical Procedure
- Weigh accurately 0.35-0.45 g BaCl2·2H2O and dissolve in 200 mL water with 1 mL dilute HCl.
- Heat to near boiling.
- Add 10 mL of hot 1 M H2SO4 dropwise with stirring.
- Digest on a steam bath for 1 hour.
- Filter through ashless paper; wash with hot water until the washings are neutral to litmus.
- Ignite at 800 C to constant mass, cool in a desiccator and weigh BaSO4.
Observations & Expected Results
Immediate white precipitate of BaSO4. Typical ignited mass from 0.40 g sample is about 0.38 g.
Worked Stoichiometric Calculations
Problem: 0.4000 g of BaCl2·2H2O gave 0.3818 g BaSO4. Calculate % Ba. (GF = 0.5884)
Working: Mass of Ba = 0.3818 g × 0.5884 = 0.2247 g. % Ba = (0.2247 / 0.4000) × 100 = 56.16%. (Theoretical Ba in BaCl2·2H2O = 56.22%, so the sample is essentially pure.)
Safety Precautions & Hazard Control
- Add H2SO4 slowly to avoid a colloidal precipitate.
- Do not use excess concentrated H2SO4; it can coprecipitate.
- Wash free of acid; residual H2SO4 chars the paper and causes spattering on ignition.
Waste Disposal Protocol
Acidic barium filtrates go to the heavy-metal waste container after neutralisation.
Viva Voce Oral Defense Questions & Answers
Q: What is reverse gravimetry?
A: Precipitating the analyte cation (here Ba2+) with an anionic precipitant (SO4 2-), instead of the usual precipitation of an analyte anion with a cation.
Q: Why wash until the washings are neutral?
A: Residual sulfuric acid chars the filter paper during ignition and can cause mechanical loss by spattering.
Q: Could BaCO3 be used as the weighing form instead?
A: No — BaCO3 is less stoichiometric on ignition and absorbs CO2/moisture; BaSO4 is stable to 1400 C and non-hygroscopic.