Separation of Nickel(II) and Copper(II) Ions in a Mixture by Paper Chromatography
To separate nickel(II) and copper(II) cations in an unknown mixture using paper chromatography with an acetone-HCl eluent and reveal separated spots using rubeanic acid and DMG.
Theoretical Foundations
Nickel(II) and copper(II) have distinct affinities for chloride ligands in organic-aqueous mixed media. In acetone-HCl eluent, copper(II) forms chlorocuprate(II) species ([CuCl3]- and [CuCl4]2-) that have high solubility in the acetone phase, migrating to Rf ≈ 0.65-0.70. Nickel(II) does not form stable chloro-complexes and remains primarily as hydrated [Ni(H2O)6]2+ bound to the cellulose stationary phase with Rf ≈ 0.08-0.10. Treatment with rubeanic acid (dithiooxamide) in ammonia vapors provides simultaneous differential color visualization: Cu2+ forms an intense dark olive-black/green coordination polymer, while Ni2+ produces a distinct blue-violet band (or brilliant red with DMG).
Required Apparatus & Chemicals
Laboratory Apparatus
- Chromatography jar with airtight cover
- Whatman No. 1 paper strips (15 × 5 cm)
- Glass capillary spotting tubes
- Atomizer spray unit
- Metric ruler
- Hair dryer (cool mode)
Chemical Reagents
- 0.1 M NiCl2 solution
- 0.1 M CuCl2 solution
- Ni2+ / Cu2+ test mixture (0.05 M each)
- Developing solvent: Acetone : concentrated HCl : H2O (87:8:5 v/v/v)
- Visualization reagent: 0.5% Rubeanic acid in ethanol
- 28% Aqueous ammonia
Step-by-Step Practical Procedure
- Equilibrate the chromatography tank with 25 mL of acetone-HCl-water mobile phase for 30 min.
- Mark a baseline 2.0 cm from the bottom edge of a Whatman No. 1 paper strip.
- Apply 2-3 uL each of NiCl2, CuCl2, and the mixed sample to marked points on the baseline; dry spots thoroughly.
- Suspend the paper in the tank and allow ascending development until the solvent front travels 12 cm.
- Remove the strip, mark the front immediately, and air dry in the fume cupboard.
- Expose the paper strip to ammonia vapor for 2 minutes to convert ions to ammine complexes and neutralize acid.
- Spray lightly with 0.5% ethanolic rubeanic acid solution.
- Measure the distances traveled by the solvent front and by the center of each colored zone, and determine Rf values.
Observations & Expected Results
Upon spraying with rubeanic acid in ammonia vapor: Cu2+ produces a sharp dark olive-green to black band at Rf ≈ 0.68; Ni2+ forms a distinct blue-violet to dark blue band at Rf ≈ 0.09. The binary mixture is completely resolved with zero spot overlap.
Worked Stoichiometric Calculations
Problem: The solvent front traveled 13.0 cm. The center of the Ni2+ spot traveled 1.2 cm; the center of the Cu2+ spot traveled 8.8 cm. Calculate the retention factors and resolution Rs (peak widths: w_Ni = 0.5 cm, w_Cu = 0.6 cm).
Working: Rf(Ni2+) = 1.2 cm / 13.0 cm = 0.092. Rf(Cu2+) = 8.8 cm / 13.0 cm = 0.677. Resolution Rs = 2 × (d_Cu - d_Ni) / (w_Cu + w_Ni) = 2 × (8.8 - 1.2) / (0.6 + 0.5) = 15.2 / 1.1 = 13.82 (Rs >> 1.5 indicates excellent baseline resolution).
Safety Precautions & Hazard Control
- Ensure spots do not contact the liquid solvent upon immersion.
- Rubeanic acid is sensitive; spray uniformly in a light mist to avoid wash-down.
Waste Disposal Protocol
Copper and nickel waste must be placed in heavy metal waste containers.
Viva Voce Oral Defense Questions & Answers
Q: What is the chemical formula and structure of rubeanic acid?
A: Rubeanic acid is dithiooxamide, H2N-C(=S)-C(=S)-NH2. It acts as a tetradentate bis-chelating agent, coordinating through both sulfur and nitrogen donor atoms to form highly insoluble, intensely colored coordination polymers with Cu2+, Ni2+, and Co2+.
Q: Why does copper migrate much faster than nickel in this system?
A: Copper(II) coordinates with chloride ions in concentrated HCl to form lipophilic chlorocuprate complexes which partition favorably into the mobile acetone phase, whereas nickel remains as the hydrophilic hydrated d8 cation [Ni(H2O)6]2+.