Chromatographic Purification: Isolating Caffeine from Tea by Column
To isolate caffeine from tea by extraction and purify it by column chromatography, checking purity by TLC and melting point.
Theoretical Foundations
Caffeine is extracted from tea with hot water, partitioned into dichloromethane, then chromatographed on silica: tannins and pigments adsorb strongly while caffeine (moderately polar) elutes with chloroform-methanol. Pure caffeine melts at 235-238 C (sublimes) and shows a single TLC spot at Rf ~0.5 in ethyl acetate-methanol.
Required Apparatus & Chemicals
Laboratory Apparatus
- Column
- Silica gel
- Separatory funnel
- TLC plates
- Melting-point apparatus
- Rotary evaporator (optional)
Chemical Reagents
- Black tea leaves
- Sodium carbonate
- Dichloromethane
- Chloroform : methanol 9:1 (eluent)
- Anhydrous sodium sulfate
Step-by-Step Practical Procedure
- Brew strong tea with sodium carbonate (keeps tannins ionised in water).
- Extract the cooled brew with dichloromethane (3 x 30 mL).
- Dry the organic layer over sodium sulfate and evaporate.
- Load the crude caffeine on a silica column.
- Elute with chloroform-methanol; collect fractions.
- Check fractions by TLC; pool caffeine fractions.
- Evaporate, weigh, and take the melting point.
Observations & Expected Results
White needle-like crystals; mp 235-238 C; single TLC spot matching authentic caffeine.
Worked Stoichiometric Calculations
Problem: 10.0 g tea yielded 0.28 g pure caffeine. What is the % yield?
Working: % = 0.28/10.0 x 100 = 2.8% (typical for black tea, 2-4%).
Safety Precautions & Hazard Control
- Dichloromethane/chloroform: fume hood; suspected carcinogens.
- Vent the separatory funnel when shaking.
- Do not let the column run dry.
Waste Disposal Protocol
Chlorinated solvents to halogenated organic waste; silica to solid waste.
Viva Voce Oral Defense Questions & Answers
Q: Why add sodium carbonate to the brew?
A: It deprotonates acidic tannins, keeping them in the aqueous layer so they do not co-extract into dichloromethane.
Q: How do TLC and mp confirm purity?
A: One TLC spot shows a single component; a sharp mp matching literature (235-238 C) confirms identity and purity.