Gran Plot for a Weak Acid: Linear Endpoint Location
To locate the endpoint of a weak-acid titration with a Gran plot using only pre-endpoint data.
Theoretical Foundations
For a weak acid titrated with strong base, before Ve the Gran function F = (V0 + Vb) x 10^-pH is linear in Vb (it tracks [H+] from the buffer equilibrium) and extrapolates to Ve. This avoids the rounded jump region typical of weak acids, giving a more objective endpoint than the derivative method when the jump is small.
Required Apparatus & Chemicals
Laboratory Apparatus
- pH meter
- Burette
- Beaker
- Stirrer
- Pipette
Chemical Reagents
- Acetic acid (~0.01 M, dilute)
- NaOH standard (0.01 M)
- Calibration buffers
Step-by-Step Practical Procedure
- Calibrate the pH meter.
- Pipette 50.0 mL of ~0.01 M acetic acid.
- Titrate with 0.01 M NaOH, recording pH each mL; stop before the jump.
- Compute F = (V0 + Vb) x 10^-pH.
- Plot F vs Vb and fit a line.
- Extrapolate to F = 0 for Ve.
- Calculate the acid molarity; compare with the derivative endpoint.
Observations & Expected Results
The Gran plot is linear; Ve agrees with the derivative method within ~1% even for this dilute weak acid.
Worked Stoichiometric Calculations
Problem: Gran fit: F = 3.10 x 10^-5 - 1.24 x 10^-6 Vb (Vb in mL). Find Ve.
Working: Ve = 3.10 x 10^-5/1.24 x 10^-6 = 25.0 mL.
Safety Precautions & Hazard Control
- Precise pH measurement is critical.
- Use only points well before the endpoint.
- Work at constant temperature.
Waste Disposal Protocol
Dilute acetate solutions to drain.
Viva Voce Oral Defense Questions & Answers
Q: Why is the Gran method valuable for weak acids?
A: Weak-acid jumps are small and rounded, making derivative endpoints uncertain; the Gran line uses stable pre-endpoint data instead.
Q: Why must points be well before Ve?
A: Near Ve the approximations behind the linear Gran function break down as water's own ionisation contributes.