Column Chromatography: Purifying Copper Sulfate from Nickel Impurity
To separate Cu2+ from Ni2+ on an alumina/cellulose column by selective elution and determine the recovery of copper.
Theoretical Foundations
On an alumina column, Ni2+ forms a more strongly retained band than Cu2+ under mildly acidic elution, or the order is tuned with HCl concentration via chloro-complex formation. Eluting with dilute HCl washes Ni2+ through at a different rate than Cu2+, giving two coloured bands (blue Cu, green Ni). Fractions are analysed spectrophotometrically or by titration; recovery = Cu recovered / Cu loaded.
Required Apparatus & Chemicals
Laboratory Apparatus
- Glass column
- Alumina or cellulose powder
- Fraction tubes
- Spectrophotometer
Chemical Reagents
- CuSO4 + NiSO4 mixture (known Cu content)
- Dilute HCl eluents (0.5 M, 2 M)
- Distilled water
Step-by-Step Practical Procedure
- Pack the column as an aqueous slurry.
- Load the Cu/Ni mixture as a narrow band.
- Elute with 0.5 M HCl, collecting 5 mL fractions.
- Note the coloured bands and pool Cu-containing fractions.
- Increase to 2 M HCl to strip Ni2+.
- Determine copper in the pooled fractions (iodometric titration or A810).
- Calculate % recovery of copper and check Ni contamination.
Observations & Expected Results
Blue copper band elutes separately from the green nickel band; recoveries of 90-98% Cu with <2% Ni are typical.
Worked Stoichiometric Calculations
Problem: Loaded 0.500 g Cu; recovered 0.472 g. What is the % recovery?
Working: Recovery = 0.472/0.500 x 100 = 94.4%.
Safety Precautions & Hazard Control
- Do not let the bed run dry.
- Handle HCl in a ventilated area.
- Load as a narrow band for clean separation.
Waste Disposal Protocol
Metal-containing fractions to heavy-metal aqueous waste; packing to solid waste.
Viva Voce Oral Defense Questions & Answers
Q: On what basis do Cu2+ and Ni2+ separate here?
A: Different adsorption affinities for the stationary phase (and different chloro-complex stabilities), giving different migration rates under the HCl gradient.
Q: How would you detect Ni contamination in the Cu pool?
A: Dimethylglyoxime test (red Ni complex) or visible spectrophotometry at Ni's absorption maximum.