Potentiometric Redox Titration: Fe2+ vs Ce4+
To titrate ferrous iron with ceric sulfate potentiometrically using a platinum indicator electrode and find the endpoint from the potential jump.
Theoretical Foundations
The Pt electrode responds to the Fe3+/Fe2+ couple before the endpoint and the Ce4+/Ce3+ couple after it, following the Nernst equation E = E0 + (0.05916/n) log([ox]/[red]). At the equivalence point the potential jumps by several hundred mV. The equivalence potential for the reaction is the weighted mean: E_eq = (E0_Fe + E0_Ce)/2 for a 1:1 electron stoichiometry (0.77 V and 1.44 V give ~1.10 V).
Required Apparatus & Chemicals
Laboratory Apparatus
- Potentiometer/pH-mV meter
- Platinum indicator electrode
- Saturated calomel reference electrode
- Burette
- Beaker
- Stirrer
Chemical Reagents
- Ferrous ammonium sulfate (~0.05 M in 1 M H2SO4)
- Ceric sulfate standard (0.05 M in 1 M H2SO4)
- 1 M H2SO4
Step-by-Step Practical Procedure
- Pipette 25.0 mL Fe2+ solution into a beaker and add 1 M H2SO4 to ~75 mL.
- Insert the Pt and calomel electrodes and record the initial potential.
- Add Ce4+ in 1 mL portions, recording E after each addition with stirring.
- Use 0.2 mL steps through the steep jump.
- Continue a few mL past the endpoint.
- Plot E vs volume and dE/dV vs volume; the peak gives Ve.
- Calculate the Fe2+ molarity.
Observations & Expected Results
E stays near 0.5-0.7 V (vs SCE), then jumps ~400 mV within a few drops at the endpoint, levelling near 1.2 V.
Worked Stoichiometric Calculations
Problem: 25.0 mL Fe2+ needed 24.4 mL of 0.0500 M Ce4+. Calculate [Fe2+].
Working: Moles Ce4+ = 0.0244 x 0.0500 = 1.22 x 10^-3 mol = moles Fe2+ (1:1). [Fe2+] = 1.22 x 10^-3/0.0250 = 0.0488 M.
Safety Precautions & Hazard Control
- Keep the medium 1 M in H2SO4; Ce4+ hydrolyses in dilute acid.
- Clean the Pt electrode (warm nitric acid or flaming) if the response is sluggish.
- Stir uniformly and wait for a stable reading.
Waste Disposal Protocol
Acidic cerium/iron waste to aqueous heavy-metal waste after neutralisation.
Viva Voce Oral Defense Questions & Answers
Q: Write the Nernst equation for this titration before the endpoint.
A: E = E0(Fe3+/Fe2+) + 0.05916 log([Fe3+]/[Fe2+]) at 25 C.
Q: Why does the Pt electrode work here?
A: Platinum is inert and conducts electrons, so it adopts the equilibrium potential of the redox couple in solution.
Q: Derive the equivalence-point potential.
A: At Ve, [Fe3+]/[Fe2+] = [Ce4+]/[Ce3+]; adding the two Nernst equations gives E_eq = (E0_Fe + E0_Ce)/2 = (0.77 + 1.44)/2 = 1.10 V vs SHE.