Conductometric Determination of Sulfate by Barium Precipitation
To determine sulfate in a sample by conductometric titration with BaCl2, following BaSO4 precipitation.
Theoretical Foundations
Ba2+ + SO4(2-) -> BaSO4(s). Before the endpoint, sulfate is replaced by chloride (2 Cl- per SO4(2-)); conductance changes only slightly because mobilities are comparable. After the endpoint, excess Ba2+ and Cl- accumulate and conductance rises. The break point gives the sulfate content; the method avoids the tedious gravimetric BaSO4 procedure.
Required Apparatus & Chemicals
Laboratory Apparatus
- Conductivity meter
- Burette
- Beaker
- Stirrer
- Pipette
Chemical Reagents
- Na2SO4 sample solution (~0.05 M)
- BaCl2 standard (0.1 M)
- Distilled water
Step-by-Step Practical Procedure
- Pipette 25.0 mL sulfate sample, dilute to ~100 mL.
- Record conductance with stirring.
- Add 0.1 M BaCl2 in 1 mL steps, recording conductance.
- Continue past the endpoint.
- Plot conductance vs volume; the intersection of the two lines is Ve.
- Calculate sulfate molarity and mg SO4(2-) in the sample.
Observations & Expected Results
Conductance is nearly flat (slight fall) before the endpoint, then rises clearly after it; the break is sharp.
Worked Stoichiometric Calculations
Problem: Ve = 11.8 mL of 0.100 M BaCl2 for 25.0 mL sample. What mass of SO4(2-) was present? (M = 96.06)
Working: Moles Ba2+ = 0.0118 x 0.100 = 1.18 x 10^-3 mol = moles SO4(2-). Mass = 1.18 x 10^-3 x 96.06 = 0.113 g.
Safety Precautions & Hazard Control
- Stir well; BaSO4 can coat electrodes and dull the response.
- Keep temperature constant.
- Standardise BaCl2 if high accuracy is needed.
Waste Disposal Protocol
BaSO4 precipitate to heavy-metal solid waste; filtrate to drain.
Viva Voce Oral Defense Questions & Answers
Q: Why is the pre-endpoint conductance nearly flat?
A: One SO4(2-) is replaced by two Cl- of similar total mobility, so the ionic conductance barely changes.
Q: Why is this faster than gravimetry?
A: No filtration, ignition or weighing of BaSO4 is needed; the endpoint comes directly from the titration curve.