CHEMVEN

pH-Metric Titration of a Mixture: HCl + Acetic Acid vs NaOH

To determine each acid in a mixture of strong and weak acids by pH-metric titration using the two endpoints.

Level: UniversitySafety: SafeTime: 2 h
Aim of Experiment: To determine each acid in a mixture of strong and weak acids by pH-metric titration using the two endpoints.

Theoretical Foundations

In a mixture of HCl and acetic acid, the first pH jump neutralises the strong acid (Ve1, endpoint ~pH 4), and the second jump neutralises the weak acid (Ve2, endpoint ~pH 8.7). Moles of HCl = M_NaOH x Ve1; moles of acetic acid = M_NaOH x (Ve2 - Ve1). The derivative curve resolves both endpoints even though indicators cannot easily distinguish them.

Required Apparatus & Chemicals

Laboratory Apparatus

  • pH meter
  • Burette
  • Beaker
  • Stirrer
  • Pipette

Chemical Reagents

  • Mixture of HCl + acetic acid (unknown ratio)
  • NaOH standard (0.1 M)
  • Calibration buffers pH 4 and 7

Step-by-Step Practical Procedure

  1. Calibrate the pH meter.
  2. Pipette 25.0 mL of the mixture, dilute and stir.
  3. Titrate with 0.1 M NaOH, recording pH in small increments through both jumps.
  4. Plot pH and dpH/dV versus volume.
  5. Locate Ve1 (first derivative peak, ~pH 4) and Ve2 (second peak, ~pH 8.7).
  6. Calculate moles and molarities of HCl and acetic acid separately.

Observations & Expected Results

Two jumps appear: a first steep rise through pH 4 and a second through pH ~8.7; the derivative shows two distinct peaks.

Worked Stoichiometric Calculations

Problem: Ve1 = 10.2 mL, Ve2 = 31.6 mL of 0.100 M NaOH for 25.0 mL mixture. Find [HCl] and [CH3COOH].

Working: Moles HCl = 0.0102 x 0.100 = 1.02 x 10^-3 mol -> [HCl] = 0.0408 M. Moles acetic = (0.0316-0.0102) x 0.100 = 2.14 x 10^-3 mol -> [CH3COOH] = 0.0856 M.

Safety Precautions & Hazard Control

  • Use small titrant increments near both endpoints.
  • Allow full electrode stabilisation at each point.
  • Keep stirring constant.

Waste Disposal Protocol

Neutralised solutions to drain.

Viva Voce Oral Defense Questions & Answers

Q: Why can't a single indicator determine both acids?

A: No single indicator range brackets both the pH ~4 and pH ~8.7 jumps; the pH curve with two derivative peaks resolves them instrumentally.

Q: Which acid is neutralised first and why?

A: HCl, the strong acid: its protons are fully available, so the first jump corresponds to its neutralisation before the weak acid's buffer region is crossed.