CHEMVEN

Gel Filtration (Size Exclusion): Desalting a Protein Sample

To desalt a coloured protein solution on a Sephadex G-25 column, separating the macromolecule from low-molecular-weight salt.

Level: UniversitySafety: SafeTime: 2 h
Aim of Experiment: To desalt a coloured protein solution on a Sephadex G-25 column, separating the macromolecule from low-molecular-weight salt.

Theoretical Foundations

In size-exclusion chromatography porous beads fractionate by molecular size: large molecules are excluded from the pores and elute in the void volume V0, while small molecules penetrate the pores and elute later, near the total volume Vt. A coloured high-MW marker (e.g. blue dextran for V0) and a small dye or salt (for Vt) bracket the separation; the protein elutes with the void peak, free of salt.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Sephadex G-25 column
  • Fraction tubes
  • Conductivity meter or AgNO3 test
  • Spectrophotometer (280 nm)
  • Measuring cylinder

Chemical Reagents

  • Protein sample in 1 M NaCl (e.g. coloured albumin or haemoglobin)
  • Blue dextran solution (void marker)
  • Distilled water / buffer eluent
  • AgNO3 test solution

Step-by-Step Practical Procedure

  1. Pack and equilibrate the Sephadex column, determining V0 with blue dextran.
  2. Load the protein-in-NaCl sample carefully onto the bed.
  3. Elute with water or dilute buffer, collecting 2 mL fractions.
  4. Test each fraction: protein by A280 or colour, salt by conductivity or AgNO3.
  5. Plot protein signal and salt signal versus fraction number.
  6. Pool the early protein peak (salt-free) and the late salt peak separately.

Observations & Expected Results

The coloured protein peak emerges first at the void volume, well before the conductivity/AgCl salt peak; pooled protein fractions give a negative chloride test.

Worked Stoichiometric Calculations

Problem: Blue dextran eluted at 12 mL (V0) and NaCl peaked at 34 mL. The column bed volume Vt is 40 mL. What is the distribution coefficient Kav of NaCl?

Working: Kav = (Ve - V0)/(Vt - V0) = (34 - 12)/(40 - 12) = 22/28 = 0.79, typical for a fully included small molecule.

Safety Precautions & Hazard Control

  • Never let a gel-filtration bed run dry; the gel cracks and resolution is lost.
  • Load the sample as a narrow band for sharp peaks.
  • Use particle-free eluents to avoid blocking the bed.

Waste Disposal Protocol

Protein and salt fractions are non-hazardous and can go down the drain; used gel to solid waste.

Viva Voce Oral Defense Questions & Answers

Q: Why does the protein elute before the salt?

A: The protein is too large to enter the gel pores so it travels only in the void volume, while NaCl diffuses into the pores and takes a longer path.

Q: What are V0 and Vt?

A: V0 is the void (excluded) volume eluted by totally excluded molecules; Vt is the total bed volume marking elution of fully included small molecules.

Q: Why is this called desalting?

A: The macromolecule is recovered in the early fractions essentially free of the low-molecular-weight salt, which elutes much later.