Two-Dimensional Paper Chromatography: Resolving Complex Dye Mixtures
To resolve a complex mixture of dyes by two-dimensional paper chromatography using two different solvent systems.
Theoretical Foundations
In 2-D chromatography the sample is developed once, the paper is dried and rotated 90 degrees, then developed in a second solvent of different selectivity. Compounds that co-migrate in the first dimension separate in the second, so the resolving power is roughly the product of the two one-dimensional separations. Two sets of Rf values (Rf1, Rf2) identify each component.
Required Apparatus & Chemicals
Laboratory Apparatus
- Square filter paper sheet (20 x 20 cm)
- Developing troughs with lids
- Pencil and ruler
- Capillary tubes
- Hair dryer (cool setting)
Chemical Reagents
- Mixture of food dyes (red, yellow, blue)
- Solvent A: isopropanol : water 3:2
- Solvent B: n-butanol : acetic acid : water 4:1:5 (upper layer)
Step-by-Step Practical Procedure
- Mark the origin 3 cm from two adjacent edges of the square paper and spot the dye mixture.
- Develop in solvent A until the front nearly reaches the far edge; remove and mark the front.
- Dry the paper thoroughly with cool air, then rotate it 90 degrees.
- Develop in solvent B at right angles to the first direction; remove and mark the front.
- Dry, outline all spots, and label them with their coordinates.
- Measure distances and compute Rf1 and Rf2 for every component.
Observations & Expected Results
Spots spread over the 2-D map rather than one line; a mixture giving 2 overlapping bands in 1-D typically resolves into 3-5 distinct spots in 2-D, each with a characteristic (Rf1, Rf2) pair.
Worked Stoichiometric Calculations
Problem: A component moved 6.0 cm in dimension 1 (front 12.0 cm) and 3.5 cm in dimension 2 (front 11.5 cm). Give its two Rf values.
Working: Rf1 = 6.0/12.0 = 0.50; Rf2 = 3.5/11.5 = 0.30. The component is identified by the pair (0.50, 0.30).
Safety Precautions & Hazard Control
- Dry the sheet completely between runs or the first solvent will contaminate the second system.
- Rotate exactly 90 degrees so the two developments are truly orthogonal.
- Mark solvent fronts the instant the paper leaves the chamber; the front fades as it dries.
Waste Disposal Protocol
Collect spent solvents in halogen-free organic waste; dry paper in general waste.
Viva Voce Oral Defense Questions & Answers
Q: What is the advantage of 2-D over 1-D chromatography?
A: Two orthogonal separations multiply resolving power, so mixtures that overlap in one solvent system can be resolved in the second.
Q: Why must the paper be dried between the two developments?
A: Residual first solvent would mix with the second solvent and destroy the orthogonal selectivity of the second run.