pH, pOH and Buffers
The pH scale compresses a trillion-fold range into 14 numbers — and buffers are why your blood stays at 7.4.
Overview & Foundations
Your blood holds its pH at about 7.4, day and night, while your cells produce acid continuously — carbon dioxide that forms carbonic acid, lactic acid from working muscle, and acids from the food you eat. A change of only a few tenths of a unit in either direction is dangerous, and a drift to 7.0 or 7.8 can be fatal, because the enzymes that run the body work only within a narrow pH window. Yet the pH barely moves. That steadiness is not an accident and it is not achieved by removing every trace of acid; it is achieved by buffers, chemical systems built to absorb added acid or alkali and release only a small change in pH in return. To understand buffers you first need the scale they defend.
The pH scale, proposed by Søren Sørensen in 1909 for work on enzymes, is a logarithmic measure of hydrogen ion concentration: pH = −log[H⁺], where [H⁺] is in moles per litre. The logarithm is not a mathematical decoration — hydrogen ion concentrations span an enormous range, from more than 1 mol/L in concentrated strong acid to below 10⁻¹³ mol/L in strong alkali, and a log scale compresses that range into manageable numbers, roughly 0 to 14 for everyday aqueous solutions. Its crucial consequence is that each step of 1 on the scale is a tenfold change in [H⁺]. Lemon juice at pH 2.2 is not a little more acidic than black coffee at pH 5.0; it is about a hundred thousand times more concentrated in hydrogen ions. Small pH differences are large chemical differences.
For calculations, two companion relationships complete the picture at 25 °C. Water itself ionises slightly, H₂O ⇌ H⁺ + OH⁻, with [H⁺][OH⁻] = 10⁻¹⁴, which gives pH + pOH = 14, where pOH = −log[OH⁻]. For a strong acid, which ionises completely, [H⁺] equals the acid concentration, so the pH follows in one step. For a weak acid only a small fraction of the molecules ionise, [H⁺] is far smaller than the concentration, and you must use the acid dissociation constant, Ka, or its logarithmic form pKa = −log Ka — you cannot simply take −log of the concentration written on the bottle. Keeping those two cases separate avoids the most frequent pH errors.
A buffer is a solution containing appreciable amounts of a weak acid and its conjugate base — ethanoic acid with sodium ethanoate is the standard school example, and the carbonic acid–hydrogencarbonate pair does the job in blood. The two components divide the defence between them. Add a small amount of acid and the conjugate base removes most of the extra hydrogen ions by forming the weak acid; add a small amount of alkali and the weak acid neutralises the hydroxide, forming water and more of the conjugate base. Because the added ions are absorbed into a large reservoir of the pair, the ratio between the two components changes only slightly, and since pH depends on that ratio, the pH changes only slightly too. A buffer does not freeze the pH exactly; it resists change, and it can be overwhelmed if enough acid or alkali is added.
The pH of a buffer is given directly by the Henderson–Hasselbalch equation, pH = pKa + log([salt]/[acid]), in the form developed from Sørensen's scale and Hasselbalch's work on blood in 1916. Read it in two parts: when the salt and acid concentrations are equal, the logarithm is zero and pH = pKa, which is why a buffer works best when its pKa is close to the pH you want to hold. Move away from equal concentrations and the pH shifts by the log of the ratio — a tenfold excess of salt over acid raises the pH by one unit above the pKa. A buffer is useful within about one pH unit either side of its pKa, and works better at higher concentrations because the reservoir is larger.
Indicators and titration curves show the same ideas from the outside. An indicator is itself a weak acid whose two forms, HIn and In⁻, have different colours, so its colour flips as the pH crosses its own pKa; you choose an indicator whose change brackets the pH at the equivalence point of your titration. A pH curve for a buffered system is telling in the opposite way — where an unbuffered titration leaps almost vertically near equivalence, a buffer curve stays shallow across the buffered region and only rises or falls steeply at the edges, once one component of the pair is nearly used up. That flat middle is the visible signature of the reservoir at work.
Buffers are therefore chosen, not found by luck. In the laboratory they hold reaction mixtures and biological samples at a set pH so enzymes and analyses behave reproducibly. In formulation they keep shampoos, medicines and foods in the pH range where they are stable and safe. In the environment, the hydrogencarbonate system in seawater and in blood, and the natural buffering of soils, blunt the effect of acid rain and metabolic acid alike — up to a limit. The chemistry in every case is identical: a conjugate pair, a ratio that changes slowly, and a logarithm that turns that slow change into a very small change in pH.
Core Chemical Concepts
- pH = −log[H⁺]; each pH unit is a tenfold change in [H⁺]
- At 25 °C, pH + pOH = 14 and [H⁺][OH⁻] = 10⁻¹⁴
- Strong acid: [H⁺] equals concentration; weak acid: use Ka, not the bottle concentration
- A buffer is a weak acid with its conjugate base in appreciable amounts
- Henderson–Hasselbalch: pH = pKa + log([salt]/[acid]); equal amounts give pH = pKa
- Buffers work best within pKa ± 1 and at higher concentrations
Governing Formulas & Laws
Definition of pH — Sørensen's logarithmic scaleFollows from [H⁺][OH⁻] = 10⁻¹⁴ for waterHenderson–Hasselbalch equation for a buffer's pHLogarithmic form of the acid dissociation constantWorked Numerical Examples
Industrial & Laboratory Applications
- Blood pH held near 7.4 by the carbonic acid–hydrogencarbonate buffer
- Laboratory buffers that keep enzymes and analyses at a controlled pH
- Shampoos, medicines and foods formulated inside a safe pH range
- Aquariums, pools and seawater, where buffering blunts pH swings
Common Student Misconceptions
Everyday Life & Real-World Relevance
- pH = −log[H⁺]; one unit = tenfold change in [H⁺]
- Equal salt and acid in a buffer → pH = pKa
- Buffer range is roughly pKa ± 1; higher concentration means larger capacity
- Added H⁺ is absorbed by the conjugate base; added OH⁻ by the weak acid
- Blood buffer: H₂CO₃ / HCO₃⁻ holding pH near 7.4
Practice & Review Questions
Scholarly Literature & References
- Atkins & de Paula, Atkins' Physical Chemistry
- Skoog, West, Holler & Crouch, Fundamentals of Analytical Chemistry
- Sørensen, S. P. L. (1909). Enzymstudien II: Über die Messung und die Bedeutung der Wasserstoffionenkonzentration bei enzymatischen Prozessen. Biochemische Zeitschrift, 21, 131–304.
- Hasselbalch, K. A. (1916). Die Berechnung der Wasserstoffzahl des Blutes aus der freien und gebundenen Kohlensäure desselben, und die Sauerstoffbindung des Blutes als Funktion der Wasserstoffzahl. Biochemische Zeitschrift, 78, 112–144.