Electroanalytical Methods

Measure with electrodes: potentiometry, voltammetry, conductometry — electricity as an analytical tool.

ANALYTICALLevel: AdvancedAcademic Reference

Overview & Foundations

Potentiometry measures voltage at zero current: ion-selective electrodes (glass pH electrode — the lab pH meter; fluoride, calcium ISEs) follow Nernstian response (59.2 mV/decade for n=1). Reference electrodes (Ag/AgCl, calomel) complete the cell. Used in potentiometric titrations — the endpoint is the steepest dE/dV.

Voltammetry applies voltage and measures current: polarography (dropping mercury electrode, Ilkovič equation), cyclic voltammetry (the duck-shaped curve diagnoses reversibility — ΔEp = 59 mV/n for reversible), anodic stripping (preconcentrate then strip — ppb metal detection). Randles-Sevcik: ip ∝ √scan rate.

Conductometry tracks conductivity during titrations (precipitation/complexometric — no indicator needed); Kohlrausch's law adds ionic contributions. Electroanalysis shines for turbid/colored samples where optical methods fail.

Core Chemical Concepts

Governing Formulas & Laws

E = E° + (0.0592/n) log [ion]
ISE response

Worked Numerical Examples

Q: A pH electrode reads −0.118 V vs a pH 7 buffer at 0 V. pH?
A: ΔE = −118 mV = −2 × 59.2 mV → 2 pH units below 7 → pH 5.

Industrial & Laboratory Applications

Common Student Misconceptions

Forgetting junction potentials
Uncompensated resistance in voltammetry

Everyday Life & Real-World Relevance

Practice & Review Questions

How does a glass pH electrode work?
H⁺ exchanges at the glass membrane, building a potential proportional to log[H⁺] — Nernstian 59.2 mV per pH unit at 25 °C.
What does cyclic voltammetry tell you?
Reversibility, electron count, and reaction mechanisms — the peak separation and shape fingerprint the redox process.